Carter Hayes

Structural Option
1000 Continental Square
King of Prussia, PA

This is a student-generated Capstone Project e-Portfolio (CPEP) produced in conjunction with the AE Senior Thesis e-Studio.

Welcome to Carter Hayes's AE Senior Thesis e-Portfolio

1000 Continetal Square Building Statistics

 

Contents

  1. General Building Data
  2. Project & Design Team
  3. Building Architecture
  4. Building Systems

General Building Data

Project Team

Building Architecture

1000 Continental Square is high-end office space, featuring large, open floor plans with uninterrupted forty-foot bays along each side of the building.  This building is located along the prominent intersection of Pennsylvania Routes 202, 76 and 422; and is in close proximity to a Pennsylvania Turnpike interchange and the King of Prussia Mall.

 

The interior is finished with top of the line materials and modern fixtures, and the entry features a two level lobby with a dramatic cantalievered walkway and staircase.

 

The envelope is mainly architectural precast panels highlighted with brick accents. Strip windows are set into the precast on three sides of the building; the fourth side is a giant, convex, reflective glass curtain wall which dominates the highway facade. Another glass curtain wall prominently marks the buildings main entrance along with six foot building numbers.

Building Systems

1000 Continental Makes use of composite steel structural frame. Composite action is achieve through 6” long ¾” diameter headed studs on a 3" 20 gage composite metal deck with a 6 ¼” slab. Typical framing is standard w shapes, W12’s for columns, W18’s for beams, and W24’s for girders. There are two standard bay sizes, 30’ x 40’ on the exterior and 30’ x 35’ in the interior. The building uses a different lateral system in each direction. In the east - west direction run two moment frames and north - south are two identical brace frames. The building’s foundations consists of standard spread footings with a continuous strip footing under the retaining walls on the ground floor.

 

Two 60,000 CFM air handeling units loacted on the roof provide the air VAV boxes, two per floor.

Power supplied to 1000 Continental Square is a 277/480 V three phase four wire system. This is stepped down by a 150 kVA transformer. All floors have four 277/480 V panelboards, four 208/120 V panelboards. An additional panel board is located on the first floor to deal with low voltage fixtures.

The building's current design only provides emergency lighing and additional lighting in common areas like lobbies and stairwells. The design for the lobby incorperates florecent pendent fixtures and wall washes, while that elevator lobby uses recessed can lights accented by a backlit tray ceiling and wall sconces. Stairwells use 4' long T-8 ceiling mounted flourecent fixtures. Metal Halide fixtures are used as decorative sconces on the exterior of the building as well as throughout the parking area.

All floors of 1000 continental are fully sprinkled. The floor slabs were increased one inch in depth to achieve a two hour rating everywhere, and all exposed steel in the floor system was sprayed with fire proofing to achieve that same two hour rating. The roof structure was only sprayed to achieve a one hour fire rating.

The main means of transportation for the occupants are the four elevators in the core of the building which service all floors. There is also a larger service elevator which also services all floors. A starewell runs from the fifth floor down to the first as a substitute for the elevator. Finally there are two stairwells next to each braced frame,centrally located in both wings of the building, which run from the roof to the basement specifically designed for emergencies.

 

Senior Thesis | The Pennsylvania State University | Architectural Engineering | AE Lab | Contact Carter Hayes
This page was last updated on January 22, 2008 , by Carter Hayes and is hosted by the AE Department © 2007